2016 KLA-Tencor BF2905 (Optical broadband plasma wafer defect inspectors)
2016 KLA-Tencor BF2905 (Optical broadband plasma wafer defect inspectors)
Contact us for price
orCall +353 (0) 87 192 1110
Description
Installation date: 2016
Down date: 2020
Still installed in Clean room
Problem discription: The tool failed optics qualification due to dead channel on CPC0.
Compared CPC-0 with CPC-1 and confirmed during TDI calibration CPC-0 detector has
abnormal pixel spike.
Error message: Illumination Profile Average Gain Out Of Range error.
Parts faulty identified:
1. CPC-0 P/N: 0676983-000 FRU ASSY,CPC ENCLOSURE GENE
2. POWER SUPPL P/N: 0356296-003 FRU ASSY,PWR SUPPLY,PS2,84VDC
Specifications
Manufacturer | KLA-Tencor |
Model | BF2905 (Optical broadband plasma wafer defect inspectors) |
Year | 2016 |
Condition | Used |
Stock Number | BM427 |